98 SERIES
THERMAL CIRCUIT BREAKER, FROM 3A UP TO 50AMP
Wide selections of terminals, bushing and caps

WATER PROOF NUT

  • Rating: 3.0Amp - 50.0Amp
  • Input power: 125/250Vac, 50Vdc, 50/60Hz
  • Interrupt capacity: 1000Amp, 125Vac; 200Amp, 250Vac
  • Dielectric strength: 1500Vac, 1 minute
  • Resettable overload capacity: 10 times rated current
  • Voltage drop: less than 0.25V
  • Insulation resistance: 500 M. ohms
  • Reset time: within 60 seconds
  • Temperature rise: less than 65 degrees in Celsius, at 100% of rated current applied continuously at 25 degree in Celsius
  • Calibration (at 25 degree)

100% of rated current: hold, no-trip
135% of rated current: trip in 1 hour
200% of rated current: within 40 seconds trip
300% od rated current: within 10 seconds trip

How to order

 

 

98-15-P1B14